• HKC Limit Switch Box, APL-series 4N (explosion-proof)
 
 
  410N (mechanical s/w)
 
APL-410N
 
Enclosure : IP 67.  EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
2-SPDT Mechanical switch 
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 
 
  411N (mechanical s/w)
 
APL-411N
 
Enclosure : IP 67.  EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
3-SPDT Mechanical switch
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 
 
  412N (mechanical s/w)
 
APL-412N
 
Enclousrue : IP 67.  EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
4-SPDT Mechanical switch
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 
 
  413N (mechanical s/w)
 
APL-413N
 
Enclosure : IP 67.  EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
2-SPST Mechanical switch
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 
 
 
 
  414N (mechanical s/w)
 
APL-414N
 
Enclosure : IP67.  EX/Proof.
 
EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
2-DPDT Mechanical switch
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 
 
  415N (mechanical s/w)
 
APL-415N
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  416N (mechanical s/w)
 
APL-416N
 
Transmitter Operating Instructions
 
- Precision analog position transmitter
 
- Operates with any voltage from 5 to 38 volts DC
 
- Polarity independent
 
- Transient protected
 
- Easy set up, non-interactive adjustment
 
- CW and CCW rotation easily accommodated
 
- Available in 4-20 mA
 
- Available with proximity switches &
 
Mechanical switch
 
 
 
- Specifications
 
Power Supply Range: 5 volts DC to 38 volts DC
 
Operating Temperature Range: -40F to 185F
 
Recommended Power Supply: 24 volts DC
 
Output Signal Range : 4 to 20 milliamperes DC
 
Load Impedance:0-10k ohms at 24 volts DC
 
Output Current Limit Internally limited to 33 mA
 
Linearity:Plus or minus 1.0%
 
Repeatability:Plus or minus. 3% of full scale
 
Power Supply Output signal changes. 018% when the supply voltageIs varied between 5 and 38 volts DC
 
 
 
  420N (proximity sensor)
 
APL-420N
 
Enclosure : IP 67.  EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
Proximity sensor (P&F NJ2-V3-N)
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 

 

  

 
 
 
  421N (proximity sensor)
 
APL-421N
 
Enclosure : IP 67. EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
Proximity sensor (Autonics PS17-5DNU
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 

 

 

 

 
 
 
  422N (proximity sensor)
 
APL-422N
 
Enclosure : IP 67. EX/Proof. EExd IIB T6 to CENELEC
 
EN 50014/50018
 
Position indicator (Open/Closed)
 
Proximity sensor (P&F NBB3-V3)
 
Proximity sensor (P&F NJ2-12GM40-E2)
 
Proximity sensor (P&F NJ4-12GM40-E2)
 
Proximity sensor (P&F NJ1.5-8GM40-N)
 
Mounting bracket (NAMUR VDE/VDI 3845)
 
 
 
 

 

DOWNLOAD PDF [SPECIFICATION]hspace=0 | DOWNLOAD PDF [DIMENSION]hspace=0 | DOWNLOAD PDF [MANUAL]hspace=0 | DOWNLOAD PDF [CATALOGUE]hspace=0 | DOWNLOAD PDF [WIRING DIAGRAM]